Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
Detail HK-7200A Toxic Gas Detector
HK-7200A Toxic Gas Detector
The Ex HK-7200A Toxic Gas Detector, based on electrochemical principle, is designed for continuous detecting and monitoring of hazardous gas leaks in ambient air and provides a 4~20mA output signal that can be connected to a controller, PLC,DCS or similar instrumentation. Supplies category:Toxic Gas Detector
Material code:HK-7200A
Manufacturer:Beijing Huakeyi Power Plant Instrument Research Institute
Introduction
The Ex HK-7200A Toxic Gas Detector, based on electrochemical principle, is designed for continuous detecting and monitoring of hazardous gas leaks in ambient air and provides a 4~20mA output signal that can be connected to a controller, PLC,DCS or similar instrumentation.
Feature
. ADVANCED MCU TECHNOLOGY.
. SMT AND INGETAL DESIGN—Enhance performance and reliability.
. CURRENT TRANSMISSION–Extremely extends the distance of signal transmission.
. CENTRALIZED POWER SUPPLY AND REGIONAL POWER SUPPLY
. LED DISPLAY—Display real-time concentration and operating statues of detector.
. SIGNAL TRANSMISSION—Send measured concentration signal to controller.
. INDOOR AND OUTDOOR USE—Suitable for the harshest environmental conditions.
. UNIQUE MAGNETIC PEN DESIGN—Operate detector through magnetic pen.
. IMPORTED CATALYTIC COMBUSTION SENSOR—Advanced performance with stable measurement, high sensitivity, anti-poisoning, and resist influence.
. SENSOR DIAGNOSTIC FUNCTION—Provide alarm and prompt while sensor fault or ageing.
Technique Data
Display
LED
Display real-time concentration and operating statues of detector
(including high alarm,low alarm,and fault alarm)
Measurement
Toxic Gases
Principle
Electrochemical
Sample Method
Diffusion
Measurement
O2, CO, H2S, H2, Cl2, SO2 and other toxic gases
Measurement Range
See below (depend on power requirements)
AccuracyP
±5%F.S
Response Time (T90)
≤60 sec at 25oC
Alarm Configuration
Two levels alarm,the alarm concentration programmable
Ambient Temperature
-20 to 50oC
Ambient Humidity
≤93%RH at 40oC (no condensation)
Atmosphere Pressure
86-106KPa
Output Signal
4-20mA
Transmission Distance
≤1000m (2.5mm2)
Power Supply
24±6VDC (centralized power supply or regional power supply)
Connection Method
3-wires
Power Consumption
≤1W
Storage Temperature
-25 to 55oC
Explosion-proof
Exd II CT6
Protection Grade
P66
Measurement
CO
H2S
CO2、、
Cl2
H2
O2
Measure range
(0~500)×
10-6
(0~50) ×10-6
(0~20)×10-6
(0~20)×10-6
(0~500)×10-6
(0~25)%VOL